[Skip to Content]
Provided by ASME The American Society of Mechanical Engineers
Banner
Turbo Expo 2026
Allianz MiCo
Milan, Italy

Conference: June 15–19, 2026
Exhibition: June 16–18, 2026
Menu
  • Technical Program
  • Tracks and Organizers
  • Policies
    • Confirm Co-Authorship
    • Presentation Requirements
    • Conflict in Ukraine
    • Code of Conduct/Anti-Harassment
  • Event Site
  • Help/Resources
    • Help Desk Calls
    • Contact Us
    • Organizer Resources
    • Author Resources
      • ASME Plagiarism Screening (iThenticate)
      • ASME Presenter Attendance Policy
      • Turbo Expo Paper Quality Standards
      • ASME Turbo Expo Journal Best Paper Guidelines
      • Conference-Specific Information and Templates
      • Copyright Transfer Form
      • Technical Presentation Tips
      • ​​​​​​​Appeal Process for the Journal of Turbomachinery
      • The Appeal Process for the ASME Journal of Engineering for Gas Turbines and Power Jerzy T. Sawicki, Ph.D., P.E., Editor
      • Indexing
      • Tutorial Handout Template
      • Poster Session Guidelines
      • Authorship and AI Tools
      • Author FAQs
  • Publication Schedule
  • Home
  • Home
  • Turbo Expo 2021 Session Gallery
  • 05-04 Topics in Instrumentation (B)
  • Hot-Wire Measurements in Non-Calibrated Conditions

59259 - Hot-Wire Measurements in Non-Calibrated Conditions 

The hot-wire anemometer is a widely used instrumentation to determine flow velocity and to investigate flow quality. The main objective of this paper is to expand the application range of the hot wire by improve the measurement accuracy under non-calibrated temperature and pressure. According to the four kinds of heat transfer derivations were carried out. Considering natural convection, heat radiation and heat conduction, and forced convection heat transfer, it is found that the forced convection heat transfer plays a dominant role, and the main factor of the change is the temperature. Forced convection heat transfer is also affected by pressure, which affects heat transfer by affecting kinematic viscosity. Based on this, a new calibration method and formula of velocity were put forward, which can be used over a range of temperature and pressure, considering the changes of physical property of the calibration scheme were verified by numerical simulation. The numerical calculated results were compared , the average error was 0.9%, the maximum error was 2.9%. The results show that the calibration method has high accuracy in a certain range. This paper provides a new solution for the calibration of hot-wire anemometer, and expand the adaptability of hot-wire anemometer in the measurement of severe external conditions.

Custom JS

double-click to edit, do not edit in source

 

Hot-Wire Measurements in Non-Calibrated Conditions

Paper Type

Technical Paper Publication

Description


Session: 05-04 Topics in Instrumentation (B)

Paper Number: 59259

Start Time: June 9th, 2021, 12:15 PM

Presenting Author: Yuexin Wang

Authors: Yuexin Wang Northwestern Polytechnical University
Huiren Zhu Northwestern Polytechnical University
Tao Guo Northwestern Polytechnical University
 

 













 

This site supports all modern browsers, such as Chrome, Firefox, Safari, and Edge. Microsoft no longer supports IE 11 as of August 2021. If you prefer to or you are required to continue using a Microsoft browser, you can use Edge.

  • ASME.ORG
  • Press
  • Terms of Use
  • Privacy Statement
  • ASME Communication Preferences
  • Community Rules

© The American Society of Mechanical Engineers

Stay Connected