59291 - Achieving Better Power Plant Guarantees Through a New Exergy-Based Approach for the Hrsg
The best assurance a customer has to maximize the performance of the entire combined cycle power plant is perfect alignment of HRSG performance guarantee metrics to this goal. Currently, HRSG equipment performance guarantees include steam generation rates and steam temperature at each pressure level plus draft loss and reheater pressure drop. This profusion of guaranteed parameters with multiple bonus/LD rates is not always well correlated to the customer’s ultimate goal of delivering MW from the bottoming cycle since the behavior of each steam generation circuit is a complex function of steam pressure, steam turbine performance, and GT exhaust temperature.
This paper proposes a solution that normalizes and combines all HRSG performance measurements into a single value directly and reliably tied to the customer value metric (which may be different for fired and unfired operation or other load points). This is achieved by expressing the HRSG performance guarantee in terms of exergy recovered to steam and plant exergy loss attributable to the HRSG (reheater pressure drop, and gas side draft loss).
This will be shown, with examples, to serve the goals of the customer to confirm by test that an HRSG delivers the promised steam exergy consistent with the plant level performance requirement.
Achieving Better Power Plant Guarantees Through a New Exergy-Based Approach for the Hrsg
Paper Type
Technical Paper Publication
Description
Session: 09-02 Gas Turbine and Power Plant
Paper Number: 59291
Start Time: June 8th, 2021, 02:15 PM
Presenting Author: Raub Smith
Authors: Raub Smith General Electric/Gas Power Systems